Sign In | Join Free | My himfr.com
Home > Low Speed Dental Handpiece >

Inner Water Spray Slow Speed Handpiece Push Button High Temperature Resistance

Medenstar Co.Ltd
Contact Now
    Buy cheap Inner Water Spray Slow Speed Handpiece Push Button High Temperature Resistance from wholesalers
     
    Buy cheap Inner Water Spray Slow Speed Handpiece Push Button High Temperature Resistance from wholesalers
    • Buy cheap Inner Water Spray Slow Speed Handpiece Push Button High Temperature Resistance from wholesalers
    • Buy cheap Inner Water Spray Slow Speed Handpiece Push Button High Temperature Resistance from wholesalers

    Inner Water Spray Slow Speed Handpiece Push Button High Temperature Resistance

    Ask Lasest Price
    Brand Name : medenstar
    Model Number : HPB002P-CA
    Payment Terms : L/C, T/T, Western Union
    • Product Details
    • Company Profile

    Inner Water Spray Slow Speed Handpiece Push Button High Temperature Resistance

    Inner Water Spray Slow Speed Handpiece Push Button High Temperature Resistance


    Description:

    1:1 gear ratio, Internal irrigation system.

    Air pressure:245-392kPa

    Atomized water pressure:200kPa

    Atomized air pressure:200kPa

    Rotation Speed:14000-20000r/min

    Push button type chuck

    Bur applicable:Φ2.35mm , Φ1.60mm

    Noise :≤70dB


    dental low speed handpiece Specification
    - E-type connector
    - Precise technology, Steady, no vibration while revolving, offering a steady operation.
    - Suitable for any E-type handpiece accords with ISO standard
    - 135°C Autoclavable, suitable for both steam and chemical autoclave
    Contra angle handpiece
    - 1:1 ratio 40,000P.M.
    - The shank of the instrument mounted therein is 2.35 mm
    - Fastening of the instruments with a turning latch
    - Autoclavable 135°C
    - For any lab or E-type motors


    Dental handpieces right use way:
    1. The need to use a clean , dry , oil-free air compressors for medical use ;
    2. The air pressure between 2.3-2.8kgf / cm2;
    3. Place the adapter with quick connector at the bottom of a combination of dental handpieces , and confirm that the card lock fixed ;
    4. Press the pedal , handpiece operation and examine whether the normal operation of the spray head . If everything is normal, you can start using the handpiece.
    After each patient use , maintenance should be done as follows
    1. First remove the diamond burs , and clean up all the teeth on dental handpieces precipitate ;
    2. Use a metal needle to clean the spray holes and fumaroles ;
    Note: The spray holes and diamond burs into 40 -degree angle , fumaroles and diamond burs to a 30 degree angle.
    3. Place the clean lubricating oil is sprayed into the axial hole 1-2 seconds ( diamond burs is plugged holes ) ;
    4. In the bottom of the handpiece were ( with / without quick connector ) two kinds of styling , make the right amount of lubricant is injected into the bottom ;
    5. The handpiece with quick connector combination ( first determine the water switch is turned off )
    6. Replace the diamond burs , surrounded by white silk cloth handpiece head ( make sure the needle does not touch the diamond burs and white gauze , so as not to tie ) ;
    7. pedal depressed for about 20 seconds , look at whether there is in white gauze on any stain. If there are stains on the white gauze , again, add oil , starting from item 4 continued routine maintenance , know that white gauze until no stain ;
    8. Finally, no more than 135 degrees Celsius temperature and high pressure sterilization.


    Maintenance:
    1. Considering safety first, please be careful to use it with full attention.
    2. Be limited to dentists who held the dental treatment qualifications.
    3. Strictly forbid decomposition and reconstruction by unauthorized.
    4. Please run point testing on outside of patients oral beforehand. If feel anomalies, please stop using immediately and contact with our after-sales center.
    5. When appears abnormal during using, please stop it immediately and contact with our after-sales center.
    6. It will cause a high noise using a center-vibration or bended bur and a handpiece of which bearing has been worn, A long time in this state will be harm to people’s hearing. Forbid using a vibration or bended bur, if appear high noise, please replace the shaft core early
    7. Do not use a bending , cracking, deformation and unqualified bur. If using it, may cause a snap, or a flying off to injury accident during operation process.
    8. Please ensure the bur chuck be clean. If with contaminant inside of it, may causes bur clamping weaken or shaft core vibration.
    9. Please run the bur under the provision rotation-speed by bur manufacturers.
    10. Do not crash, especially to avoid falling.
    11. Please install a bur or a standard stick before using.
    12. Aslo remember to install a bur or a standard stick when not in using.
    13. Please unload the bur and handpiece when the running stopped in completely.

    Quality Inner Water Spray Slow Speed Handpiece Push Button High Temperature Resistance for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Medenstar Co.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)